1. Equipment Introduction
1.1 Overview
Air conditioning is an air conditioner, which is a device that uses artificial means to adjust and control the temperature, humidity, flow rate and other parameters of the ambient air in a building or structure. Air conditioning has become an indispensable part of people's modern life.
The refrigeration principle of air conditioning is that the compressor compresses the gaseous Freon into high-temperature and high-pressure gaseous Freon, and then sends it to the condenser (outdoor unit) to dissipate heat and become liquid Freon at room temperature and high pressure, so the outdoor unit blows out hot air. Liquid Freon enters the evaporator (indoor unit) through the capillary tube. The space suddenly increases and the pressure decreases. The liquid Freon will vaporize and become gaseous low-temperature Freon, thereby absorbing a large amount of heat. The evaporator will become cold, and the fan of the indoor unit will blow the indoor air through the evaporator, so the indoor unit blows out cold air.
Air conditioning is divided into many types according to the cooling capacity demand, and commercial air conditioning is one of them. Compared with ordinary household air conditioners, commercial air conditioners generally require a larger cooling distance span. Ordinary air conditioners suffer very large losses when transporting cold energy through pipelines. If thermal insulation materials are used, the cost will increase. Secondly, compared with ordinary household air conditioners, the condenser and evaporator of commercial air conditioners use gas-liquid convection to efficiently exchange heat. This heat exchange method has a very high heat exchange efficiency compared to air cooling. Therefore, choosing commercial air conditioners is the best choice. It has low use and maintenance costs, large cooling capacity, and a large cold transport span.
MRB3714E2 commercial air conditioner training station is a teaching device that simulates commercial air conditioners. The training station can demonstrate the basic commercial air conditioning refrigeration principles and provide high-quality air conditioning skills training for students or staff.
1.2 Features
(1) The product has excellent safety.
(2) The product adopts a modular design, the equipment is small in size and the functional division is clear, making the experimental principle clearer.
(3) The product uses excellent manufacturing materials to maximize the service life and maintenance cycle of the equipment.
(4) The product has reliable stability and can ensure the correct conduct of the experiment.
2. Technical parameters
Input power: three-phase five-wire AC400V 50~60Hz
Dimensions:
Cooling unit 1030mm*580mm*1550mm
Forced ventilation cooling tower 1310mm*710mm*1280mm
Air handling unit 1160mm*960mm*1110mm
Weight:
Cooling unit <201kg
Forced ventilation cooling tower <140kg
Air handling unit <124kg
Working conditions: Ambient temperature -10℃~+40℃; relative humidity <85% (25℃).
Refrigerant: R32A
3. Component list and detailed introduction
3.1 Main part
No Name
1 Forced draft cooling towers
2 Condenser circulating water pumps
3 Air handling units
4 Electrical control boxes for commercial air conditioners
5 Chillers
3.2 Electrical box part
No Name
1 HMI
2 Multi-function meter
3 Emergency stop button
4 Control panel of chiller
5 Low pressure indicator
6 High pressure indicator
3.3 Equipment Configuration List
No Name Qty
Component 1 Cooling unit 1
Component 2 Compressor 1
Component 3 Condenser shell and tube heat exchanger 1
Component 4 Cooling unit water pump 1
Component 5 Cooling water tank 1
Component 6 Forced ventilation cooling tower 1
Component 7 Forced circulation fan 1
Component 8 Condenser circulating water pump 1
Component 9 Float water level controller 1
Component 10 Air handling unit 1
Component 11 Air heat exchanger 1
Component 12 Air heat exchange fan 1
Component 13 HMI 1
Component 14 Multi-function meter 1
Component 15 Low pressure gauge 1
Component 16 High pressure gauge 1
3.4 Accessories
No Name Qty
1 Transparent water pipes of various sizes 5
4. Experiment list
Experiment 1: Understand the electrical circuit and pipeline connection experiment of the commercial air-conditioning training station
Experiment 2: Understand the first water injection and automatic water injection function experiment of the commercial air-conditioning training station
Experiment 3: Understand the control experiment of the electrical equipment of the commercial air-conditioning training station
Experiment 4: Understand the real-time data acquisition and display function of the sensor of the commercial air-conditioning training station
Experiment 5: Understand the simulated fault function experiment of the commercial air-conditioning training station