Whatsapp: 0086-15153106200

Didactic Station for Control Level, Flow, Pressure and Temperature educational equipment lab equipment fluid mechanics lab equipment

Item No.: MR006
Didactic Station for Control  Level, Flow, Pressure and Temperature educational equipment lab equipment fluid mechanics lab equipment
Description
MR006 Didactic Station for Control  Level, Flow, Pressure and Temperature educational equipment lab equipment fluid mechanics lab equipment
Actuators, position valves, ball valve and warmer 
Application for teaching continuous, discontinuous and automatized processes 
2 deposits 
Software 
Component installation: Montage frame with profifile panel and tubing system 
HMI Screen for process visualization 
Sensors: Capacitive, flfloater, ultrasonic, flow, pressure and temperature 
Sensors: 8 
Electric tension 120 to 240V 
With polycarbonate deposit as liquid storage 


Compact station type 
Universal control 
It is be able to configure and program the PLC by software 
It is guarantee the learning of difference programming languages with controllers 
It is be able to make the projects in the HMI 
It is be able to operate the inversor of frequency by the digital and analog controls 
It is be able to make PID control in closed circuit with proportional parameter selection, 
integral and derivative. Adjust the value of the preset and control ON/OFF of temperature. 
Include user manual 
Include all connection cables 
It include at least 7 licenses for the sea of the HMI and PLC 
Include 1 place with at least 40 I/O digital and 7 I/O analog and MPI communication 
protocols, Profibus-DP and Profinet 
Include 1 remote unit of Profinet 
Include 1 expansion for the Hart input 
The HMI It is be with touch screen color screen of at least 10.4” 


Include 2 tanks made in methacrylate of 20L 
Include a inversor of frequency for the activation of the pump 
Include 1 centrifuge pump of 0.5cv 
Include a warming resistor tubular type of 1000W 
Include temperature sensor PT100 
Include 2 ultrasonic sensors of analog output 
Include 1 sensor of flow with Hart 
Include at least 4 sensors with capacitive level 
Include 1 pressure transducer 
Training