Installation technology: losses in valves and fittings Vocational Training Equipment Heat Transfer Laboratory Equipment

Item No.: MR-HL 113
Installation technology: losses in valves and fittings Vocational Training Equipment Heat Transfer Laboratory Equipment
Description
MR-HL 113 Installation technology: losses in valves and fittings Vocational Training Equipment Heat Transfer Laboratory Equipment

Description
trainer for heating and sanitary engineering
pressure losses in standard valves and fittings
Pressure losses occur in pipe systems as a result of friction and turbulence. In practice, the use of shut-off valves and fittings causes pressure losses that need to be taken into consideration when designing pipe networks.
The MR-HL 113 unit can be used to investigate the pressure losses of different shutoff valves and fittings. The pipe elements used are commercially standard components in heating and sanitary engineering. The clear panel is mounted on a sturdy, movable frame.

The trainer consists of five pipe sections, in each of which different shut-off valves and fittings are fitted. The pipe sections can be individually selected via ball valves.
One of the pipe sections is transparent with a transparent ball valve in order to visualise the flow conditions upstream and downstream of a shut-off valve. The flow is adjusted using valves in the inlet and outlet and read on a rotameter.
The pressure measuring points in the pipe system are designed as annular chambers and are located directly upstream and downstream of the valves and fittings, ensuring a precise pressure measurement. The sensors are connected in pairs to a differential pressure meter and the respective differential pressure read on the display.

Learning objectives/experiments
pressure losses in valves and fittings
measuring the pressure difference
effect of the valve orifice shape on the pressure loss
effect of the flow velocity
determination of resistance coefficients
comparison between experiment and calculation

Specification
[1] investigation of the pressure losses at various shutoff valves and fittings
[2] pipe elements are commercially standard components in heating and sanitary engineering
[3] clear panel mounted on a sturdy, movable frame
[4] pipe sections can be individually selected via ball valves
[5] water connections with quick-release couplings
[6] flow can be adjusted via valves
[7] flow measurement using rotameter
[8] differential pressure measurement via differential pressure meter with display

Technical data
Ball valve, plastic, transparent, Ø: DN32
Ball valve, steel, Ø: DN15
Angle seat valve, Ø: DN15
Screw-down valve, Ø: DN15
Gate valve, Ø: DN15
Differential pressure meter
Measuring ranges
flow rate: 2001700L/h
pressure: ±200mbar

LxWxH: 1650x700x1850mm
Weight: approx. 90kg
Required for operation
water connection, drain
Scope of delivery
1 trainer
1 differential pressure meter
1 set of connecting hoses
1 set of instructional material